SGR Battery Cable SAE J1127

Kalas Logo

SGR BATTERY CABLE SAE J1127

Kalas SGR BATTERY CABLE

Construction

Conductor material: Bare Copper
Gauge: 350 MCM – 6
Insulation material: EPDM
Operating Temperature: -40°C to 105°C
Meets Requirements: SAE J1127;
UL approved product upon request 

Applications

For use between battery terminal & starter in boats, buses, cars, lift trucks, RV’s, tractors and trucks.

Features

  • Custom print, special stranding and packaging are available upon request.
  • Resistant to acid, abrasion, alkalis, coolant, diesel fuel, ethanol, flame, gas, ozone, power steering fluid, oil and transmission fluid.
  • Meets the Battery Cable requirements of UL 558 paragraph 8.1 item (f) and UL 583 paragraph 12.1 item (f).

View Complete Specifications

Cable You Can Trust.
Customer Service that Cares.

Over the past 60 years, Kalas has become a leading manufacturer of copper wire & cable vertically and strategically integrated for superior material control. We are dedicated to delivering dependable solutions, constantly evolving in order to find new ways to serve our customers, become better and build our collaborative partnerships and technical expertise.

Let us know how we can serve your wire & cable needs.

Get to know Kalas

Click the links to the right to learn about our foundation, connect with us on social media or read our latest articles at our blog. 

Kalas Blog

Still Have a Question? We'd love to help.

Let us know what questions you have about Kalas wire & cable.

We love to answer questions and make the process of ordering and creating the cable you need as smooth as possible!

SGR Battery Cable UL 105°C

Kalas Logo

SGR BATTERY CABLE
UL 105°C

Kalas SGR BATTERY CABLE

Construction

Conductor material: Bare Copper
Gauge: 4/0 – 6
Insulation material: EPDM
Operating temperature: -40°C to 105°C
Meets Requirements: SAE J1127, UL 4127

Applications

SGR Battery Cable UL 105°C is for use between battery terminal & starter and grounding, on boats, buses, cars, lift trucks, RV’s, tractors and trucks.

Approved for use for Electric-Battery-Powered Industrial trucks (Standard UL-583) and Industrial Trucks, Internal Combustion Engine-Powered (Standard UL-558)

Type SGR, Surface Vehicle Cable, Low-Voltage Battery Cable, in accordance with UL 4127. Type SGR, Surface Vehicle Cable, Low-Voltage Battery Cable Classified in Accordance with SAE J1127.

Features

  • Resistant to acid, abrasion, alkalis, coolant, diesel fuel, ethanol, flame, gas, ozone, power steering fluid, oil and transmission fluid.
  • Custom print, special stranding and packaging are available upon request for SGR Battery Cable UL 105°C.

View Complete Specifications

Cable You Can Trust.
Customer Service that Cares.

Over the past 60 years, Kalas has become a leading manufacturer of copper wire & cable vertically and strategically integrated for superior material control. We are dedicated to delivering dependable solutions, constantly evolving in order to find new ways to serve our customers, become better and build our collaborative partnerships and technical expertise.

Let us know how we can serve your wire & cable needs.

Get to know Kalas

Click the links to the right to learn about our foundation, connect with us on social media or read our latest articles at our blog. 

Kalas Blog

Still Have a Question? We'd love to help.

Let us know what questions you have about Kalas wire & cable.

We love to answer questions and make the process of ordering and creating the cable you need as smooth as possible!

SGR Battery Cable 140°C

Kalas Logo

SGR BATTERY CABLE 140°C

Kalas SGR BATTERY CABLE

Construction

Conductor material: Bare Copper
Gauge: 4/0 – 4
Insulation material: EPDM
Operating Temperature: -60°C to 140°C
Separator: Paper
Meets Requirements: SAE J1127

Applications

For use between battery terminal & starter in boats, buses, cars, lift trucks, RV’s, tractors and trucks.

Features

  • Resistant to acid, abrasion, alkalis, coolant, diesel fuel, ethanol, flame, gas, power steering fluid, oil and transmission fluid.

  • Cable abrasion is 40% better than SAE SGX cable while maintaining the flexibility of flexible rubber SGR cable.
  • Operating temperature -60°C to 140°C exceeding SAE’s -40C requirement and SGR3’s 125C requirement.
  • Approved for use for Electric-Battery-Powered Industrial trucks (Standard UL-583) and Industrial Trucks and Internal Combustion Engine-Powered (Standard UL-558).
  • Special stranding and packaging available upon request.

View Complete Specifications

Cable You Can Trust.
Customer Service that Cares.

Over the past 60 years, Kalas has become a leading manufacturer of copper wire & cable vertically and strategically integrated for superior material control. We are dedicated to delivering dependable solutions, constantly evolving in order to find new ways to serve our customers, become better and build our collaborative partnerships and technical expertise.

Let us know how we can serve your wire & cable needs.

Get to know Kalas

Click the links to the right to learn about our foundation, connect with us on social media or read our latest articles at our blog. 

Kalas Blog

Still Have a Question? We'd love to help.

Let us know what questions you have about Kalas wire & cable.

We love to answer questions and make the process of ordering and creating the cable you need as smooth as possible!

SGT Battery Cable

Kalas Logo

SGT Battery Cable

Kalas SGT BATTERY CABLE

Construction

Conductor material: Bare Copper
Gauge: 4/0 – 6
# Conductors: 1
Insulation material: PVC (80°C or 105°C)
Operating temperature: -40°C to 80°C
or 105ºC
Meets Requirements: SAE J1127 

Applications

For use between battery terminal & starter and grounding, on boats, buses, cars, lift trucks, RV’s, tractors and trucks.

Features

  • Special stranding and packaging available upon request.
  • Available in clear and custom tinted clear colors.
  • Resistant to acid, abrasion, alkalis, coolant, diesel fuel, ethanol, flame, gas, ozone, power steering fluid, oil and transmission fluid.
  • Meets the Battery Cable requirements of UL 558 paragraph 8.1 item (f) and UL 583 paragraph 12.1 item (f).

View Complete Specifications

Related Part Numbers

300069.XX.001
300069.XX.003
300068.XX.001
300068.XX.003 

300067.XX.001
300067.XX.003
300066.XX.001
300066.XX.003 

300065.XX.001
300065.XX.003
300064.XX.001
300064.XX.003 

300063.XX.001
300063.XX.003
300062.XX.001
300062.XX.003

Cable You Can Trust.
Customer Service that Cares.

Over the past 60 years, Kalas has become a leading manufacturer of copper wire & cable vertically and strategically integrated for superior material control. We are dedicated to delivering dependable solutions, constantly evolving in order to find new ways to serve our customers, become better and build our collaborative partnerships and technical expertise.

Let us know how we can serve your wire & cable needs.

Get to know Kalas

Click the links to the right to learn about our foundation, connect with us on social media or read our latest articles at our blog. 

Kalas Blog

Still Have a Question? We'd love to help.

Let us know what questions you have about Kalas wire & cable.

We love to answer questions and make the process of ordering and creating the cable you need as smooth as possible!

SGX Battery Cable

Kalas Logo

SGX BATTERY CABLE

Kalas SGX BATTERY CABLE

Construction

Conductor material: Bare Copper
Gauge: 4/0 – 6
Insulation material: XLPE
Operating temperature: -40°C to 125°C
Meets requirements: SAE J1127

Applications

For use between battery terminal & starter and grounding, on boats, buses, cars, lift trucks, RV’s, tractors and trucks

Features

  • Resistant to acid, abrasion, alkalis, coolant, diesel fluid, ethanol, flame, gas, ozone, power steering fluid, oil, and transmission fluid.
  • Meets the Battery Cable requirements of UL 558 paragraph 8.1 item (f) and UL 583 paragraph 12.1 item (f).
  • Special stranding and packaging are available upon request.
  • Custom print available upon request.

View Complete Specifications

Cable You Can Trust.
Customer Service that Cares.

Over the past 60 years, Kalas has become a leading manufacturer of copper wire & cable vertically and strategically integrated for superior material control. We are dedicated to delivering dependable solutions, constantly evolving in order to find new ways to serve our customers, become better and build our collaborative partnerships and technical expertise.

Let us know how we can serve your wire & cable needs.

Get to know Kalas

Click the links to the right to learn about our foundation, connect with us on social media or read our latest articles at our blog. 

Kalas Blog

Still Have a Question? We'd love to help.

Let us know what questions you have about Kalas wire & cable.

We love to answer questions and make the process of ordering and creating the cable you need as smooth as possible!